8. Electrical connection
Only skilled and qualified personnel may carry out the electrical
connection according to the wiring diagram!
Respect the instructions of the VDE (Association for Electrical, Electronic
& Information Technologies) and of the local network operators for the
installation to be provided by the customer!
Only use cables that are suitable for the operating range!
Observe the switching time of the magnetic switch when designing a
safety circuit. Adhere to basic and reliable safety principles as per
DIN EN ISO 13849 for electrical components.
8.1 Wiring diagram
Connection wires:
brown
yellow
white
green
Identification arrow
We recommend to use customary RC combinations or a suitable varistor
(e.g. 0,1 μF/100Ω) as inductive consumer to extend the contact life of the magnetic switch.
Resistance value (Ω) and power rating (W) depend on customer indications.
We suggest to use silicon cables free of acetic acid for the further connection cable in the
area „connecting housing inside“.
Caution