ifs MC352-4P-2S-V2 Скачать руководство пользователя страница 2

Copyright 

 

© 2022 Carrier. All rights reserved. Specifications subject to change without 

prior notice.  
This document may not be copied in whole or in part or otherwise 

reproduced without prior written consent from Carrier, except where 

specifically permitted under US and international copyright law. 

Trademarks and 

patents 

 

IFS

 names and logos are a product brand of Aritech, a part of Carrier. 

Other trade names used in this document may be trademarks or registered 

trademarks of the manufacturers or vendors of the respective products. 

Manufacturer 

 

PLACED ON THE MARKET BY:

 

Carrier Fire & Security Americas Corporation Inc.

 

13995 Pasteur Blvd, Palm Beac

h Gardens, FL 33418, USA

 

AUTHORIZED EU REPRENSENTATIVE:

 

Carrier Fire & Security B.V.

 

Kelvinstraat 7, 6003 DH Weert, Netherlands

 

FCC compliance  

Class A

: This equipment has been tested and found to comply with the 

limits for a Class A digital device, pursu

ant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. 

This equipment generates, uses, and can radiate radio frequency energy 

and, if not installed and used in accordance with the instruction manual, 

may cause harmful interference to radio communications. Operation of this 

equipment in a residential area is likely to cause harmful interference in 

which case the user will be required 

to correct the interference at his own 

expense. 

FCC conditions  

This device complies with Part 15 of the FCC Rules. Operation is subject to 

the following two conditions: 

 

(1) This device may not cause harmful interference. 
(2) This Device must accept any interference received, including 

interference that may cause undesired operation.

 

ACMA compliance 

 

Notice! 

This is a Class A product. In a domestic environment this product 

may cause radio interference in which case the user may be required to 

take adequate measures.

 

Product warnings and 

disclaimers 

 

 

THESE 

PRODUCTS ARE INTENDED FOR SALE TO AND 

INSTALLATION BY QUALIFIED PROFESSIONALS. CARRIER FIRE & 

SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON 

OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED 

DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR 

EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY 

RELATED PRODUCTS.

 

For more information on warranty disclaimers and product safety 

information, please check https://firesecurityproducts.com/policy/product

-

warning/ or scan the following code:

 

Certification 

 

  

  

   

   

 

EU directives 

 

This product and - if applicable - the supplied accessories too are marked 

with "CE" and comply therefore with the applicable harmonized European 

standards listed under the EMC Directive 2014/30/EU, the RoHS Direc

tive 

2011/65/EU.

 

Содержание MC352-4P-2S-V2

Страница 1: ...MC352 4P 2S V2 User Manual P N 1041 EN REV B ISS 13JUL22...

Страница 2: ...radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FC...

Страница 3: ...orted municipal waste in the European Union See the product documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lea...

Страница 4: ......

Страница 5: ...ers 3 Intended Use 4 Advisory messages 4 Package contents 5 Hardware Introduction 6 Switch Front Panel 6 LED Definition 8 Switch Upper Panel 9 Wiring the Power Inputs 9 Wiring the Faulty Alarm Contact...

Страница 6: ...preparation of this manual to ensure the accuracy of its contents Carrier assumes no responsibility for errors or omissions Product Warnings YOU UNDERSTAND THAT A PROPERLY INSTALLED AND MAINTAINED ALA...

Страница 7: ...tery is replaced by an incorrect type Dispose of batteries according to the instructions Contact your supplier for replacement batteries Warranty Disclaimers CARRIER HEREBY DISCLAIMS ALL WARRANTIES AN...

Страница 8: ...rpose it was designed for refer to the data sheet and user documentation For the latest product information contact your local supplier or visit us online at firesecurityproducts com The system should...

Страница 9: ...4P 2S V2 Open the box of the Industrial Gigabit PoE Switch and carefully unpack it The box should contain the following items Industrial Gigabit PoE Switch x 1 User Manual x 1 DIN Rail Kit x 1 Wall Mo...

Страница 10: ...rfaces and LED indicators Front View Figure 1 MC352 4P 2S V2 Front View PoE Power Usage LED The front panel of the Industrial Gigabit PoE Switch has four LEDs that indicate PoE Power Usages of 30W 60W...

Страница 11: ...two SFP ports to be redundant while the other 5 ports are in operation Redundancy Overview The Industrial Gigabit PoE Switch provides rapid link fiber redundancy for critical Ethernet applications the...

Страница 12: ...evice is not a PoE powered device PD SFP Interface Port 5 to Port 6 LED Color Function 1000 LNK ACT Green Light Indicates the port is running at 1000 Mbps and successfully established Blinking Indicat...

Страница 13: ...ector on the top panel of Industrial Gigabit PoE Switch is used for two redundant power inputs Please follow the steps below to insert the power wire Caution When performing any of the procedures like...

Страница 14: ...ting the wires the Industrial Gigabit PoE Switch will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the...

Страница 15: ...MC352 4P 2S V2 User Manual 11 Note EMD Lightning DAMAGE IS NOT CONVERED UNDER WARRANTY...

Страница 16: ...4P 2S V2 Mounting the DIN rail The DIN rail bracket is screwed on the Industrial PoE Switch when shipped You need an Industrial PoE Switch when replacing the wall mount application with DIN rail appl...

Страница 17: ...l 1 Loosen the screws to remove the DIN rail bracket from the Industrial PoE Switch 2 Place the wall mount plate on the rear panel of the Industrial PoE Switch 3 Use the screws to attach the wall moun...

Страница 18: ...er 1 Pin 3 4 for fault alarm Pin 5 6 for Power 2 Power Requirements 12 to 56 VDC 7 A max Redundant power with reverse polarity protection Alarm Provides one relay output for power failure Alarm relay...

Страница 19: ...Compliance FCC Part 15 Class A CE Stability Testing IEC 60068 2 32 free fall IEC 60068 2 27 shock IEC 60068 2 6 vibration Standards Compliance IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3a...