background image

ZZ1102 I/O module

4

4  Items supplied

 

1x CR0403 BasicController, pre-programmed

The BasicController is delivered pre-programmed� If ordered separately, the BasicController is not 

pre-programmed�

 

1x EC0401 cover with cable seal for BasicController

 

1x E3M171 CAN/power adapter cable to connect the BasicController to the O3M 3D sensor

 

● 1x EC9206 connection cable with contact housing for BasicController (inputs)

 

● 2x EC9207 connection cable with contact housing for BasicController (outputs)

 

1 x instructions for set-up

5  Function

The BasicController included in the set is supplied with voltage and connected to the O3M 3D sensor via 

the CAN/power adapter cable�
The O3M 3D sensor communicates with the BasicController via the CAN bus 
The BasicController CR0403 translates the data of the O3M 3D sensor on the inputs and output pins�

A

B

C

D

E

F

N2

P/N1

LED

CAN

IN

OUT

PWR

Fig� 1: Overview 

Содержание ZZ1102

Страница 1: ...Instructions for set up O3M I O module ZZ1102 80282602 00 04 2020 UK A B C D E F N P N ...

Страница 2: ...nd further information at www ifm com You will find detailed instructions technical data approvals and further information using the QR code on the unit packaging or at www ifm com 1 1 Symbols used Instruction Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings...

Страница 3: ... or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the devices or incorrect use by the operator Installation electrical connection set up programming configuration operation and maintenance of the devices must be carried out by personnel qualified and authorised for the respective activity Protect units and cables agains...

Страница 4: ...6 connection cable with contact housing for BasicController inputs 2x EC9207 connection cable with contact housing for BasicController outputs 1 x instructions for set up 5 Function The BasicController included in the set is supplied with voltage and connected to the O3M 3D sensor via the CAN power adapter cable The O3M 3D sensor communicates with the BasicController via the CAN bus The BasicContr...

Страница 5: ...120 s For the correct rating of the overcurrent protection device take the technical data of the device and wiring into account The separation of external circuits must comply with UL 61010 2 201 Figure 102 Disconnect power before connecting the device For cable lengths 30 m use an additional protection against surge voltages to IEC 61000 4 5 The IP rating indicated in the data sheet is only guara...

Страница 6: ... via 6 3 x 0 8 mm blade male terminals on the front of the BasicController Block C inputs and Block F outputs are pre programmed Connect the BasicController via these terminal strips 7 2 1 The BasicController features an application specific configuration The configuration is also used as part of application packages e g O3M Area Surveilliance ZZ1103 N2 2 3 1 A B C D E F N2 P N1 Inputs A B C Outpu...

Страница 7: ... 01 binary output inverted linked with logic O3M digital output 72 OUT 02 binary output inverted linked with logic O3M digital output 73 OUT 03 binary output inverted linked with logic O3M digital output 74 E OUT 04 binary output inverted linked with logic O3M digital output 75 OUT 05 binary linked with logic O3M digital output 76 OUT 06 binary linked with logic O3M digital output 77 OUT 07 binary...

Страница 8: ...s available for download www ifm com 7 2 1 Connect BasicController A B C D E F N2 P N1 Connect cable Connect CAN power adapter cable to P N1 Plug EC9206 connection cable with contact housing onto input strip C Plug EC9207 connection cable with contact housing into output strip F If necessary plug the second EC9207 connection cable onto output strip D or E A B C D E F N2 P N1 LED Mount cable seal o...

Страница 9: ...ovided in the BasicController Press the cover on Move the locking lever 1 back into its initial position C Inputs F Outputs Connect the M12 connector of the CAN power adapter cable to the O3M 3D sensor 7 1 Connect the two twisted wires of the CAN power adapter cable to a power supply Blue GND brown L 24 V Assign the lines to the inputs and outputs of the BasicController as required Take pre progra...

Страница 10: ...t e g BUSOFF 250 ms 250 ms 250 ms 250 ms 250 ms 250 ms 250 ms 250 ms System runs normally standard IO module 1500 ms 500 ms System runs normally configured IO module 1500 ms 50 450 ms Device incompatible or not working 1500 ms 500 ms Connection establishment O3M 3D sensor not accessible 150 ms 100 150 ms 100 150 ms 100 150 ms 1100 ms Calibration active O3M 3D sensor not accessible 150 ms 100 150 m...

Страница 11: ...ED calibration connection establishment etc Table 2 LED indication of the operating states 9 Set up The BasicController is pre programmed for the application 7 2 Table 1 and can be put into operation directly after installation and electrical connection If further input and output signals are required they can be defined in the logic of the O3M 3D sensor with the help of ifm Vision Assistant ...

Отзывы: