2
1 Functions and features
The diagnostic electronics has 2 analogue inputs and 4 dynamic inputs. These
inputs can be used for process value monitoring, vibration monitoring, vibration
diagnostics or analysis of other dynamic signals.
2 Symbols used
►
Instructions
Important note
Non-compliance may result in malfunction or interference.
3 Installation
►
Disconnect the system from power before installation.
►
Mount the unit in a control cabinet with a protection rating of at least IP 54 to
ensure protection against accidental contact with dangerous contact voltages
and against atmospheric influence. The control cabinet has to be installed in
accordance with local and national regulations.
►
Mount the unit vertically on a DIN rail.
►
Leave enough space between the unit and the top or bottom of the control
cabinet to enable air circulation and to avoid excessive heating.
3.1 Installation instructions
Electrostatic discharge
The device contains components that can be damaged or destroyed by
electrostatic discharge.
►
When handling the device, observe the necessary safety precautions against
electrostatic discharge (ESD) according to EN 61340-5-1 and IEC 61340-5-1.
►
In order to dissipate electrostatic charges, the unit may only be operated on a
grounded DIN rail.