4
6 Settings
The unit and the parameters are set via the teach button
6.1 teach button
6.1.1 Start programming mode
►
Press the teach button for 2 s...6 s.
>
Yellow status LEDs 1/2 flash (1 Hz), the unit is in the programming mode.
If programming has not been completed successfully, the unit returns to the
previous setting.
6.1.2 Set output response
►
→ 6.1.1).
► Position the object in P1 (Fig. 1 or 2).
►
Press the teach button for 1 s.
>
Yellow status LEDs 1/2 flash (2.5 Hz), P1 setting is completed.
► Position the object in P2 (Fig. 1 or 2).
►
Press the teach button for 1 s.
>
Yellow status LEDs 1/2 flash briefly (4 Hz), P2 setting is completed.
6.1.3 Invert output response
►
Press the teach button for > 6 s.
>
Yellow status LEDs 1/2 flash (> 10 Hz).
>
Yellow status LEDs 1/2 flash briefly (> 4 Hz).
> Output function is inverted.
6.1.4 Restore factory setting
►
Align the unit so that no echo is received.
>
Green echo LED off.
►
→ 6.1.1).
►
Press the teach button for 1 s.
>
Yellow status LEDs 1/2 flash briefly (4 Hz), factory setting is restored.