Ultrasonic flow meter
SU2020 SU2021 SU2621 SU8020 SU8021 SU8621 SU9020 SU9021
21
Parameter
Explanation
FOUx
Behaviour of output OUTx in case of an error
FProx
Counting method of the totaliser: consideration of the direction of flow
FrPx
Frequency signal that is output when the upper measured value (MEW or FEPx) is reached.
FSPx
Frequency start point for OUTx = Lower measured value from which a frequency signal is output
(only for temperature measurement).
Guide
Activation of the guided installation (wizard)
ImPRx
Totaliser function: pulse signal (ImPR = YES) or switching signal (ImPR = NO)
ImPSx
Pulse value (= flow value at which 1 pulse is provided)
LanG
Language selection for the display
LED.M
Setting of the operating status LED
LFC
Low flow cut-off (= flow value below which flow is evaluated as standstill)
oux
Output configuration for output OUTx (e.g. switching output with hysteresis function)
P-n
Output polarity for the switching outputs
rES
Reset to factory settings (Back to Box) or reset of parameter settings (application reset).
rPx
Reset point for switching output OUTx with hysteresis function
rTo
Setting of the totaliser reset (manually or time-controlled)
S.FLW
Simulated flow value in simulation mode
Sig.Q
Switching signal for signal quality monitoring
S.On
Starts the simulation mode
S.Tim
Duration of the simulation in minutes
S.TMP
Simulated temperature value in simulation mode
SELx
Process value for output OUTx
SPx
Switch point for switching output OUTx with hysteresis function
uni.F
Standard unit of measurement for flow
uni.T
Standard unit of measurement for temperature
Vol.L
Current counter reading for totaliser Vol.L over the whole lifetime
Vol.x
Current counter reading for totaliser Vol.x