UK
SmartModule CR2520
27
Index
S-Idx
Name
Type
Default
Description
2014
0
number PWM outputs
ro
u8
7
1
set value PWM chan 16
rw
u16
0
PWM value 0 … 1000 out 0
2
set value PWM chan 17
rw
u16
0
PWM value 0 … 1000 out 1
3
set value PWM chan 18
rw
u16
0
PWM value 0 … 1000 out 2
4
set value PWM chan 23
rw
u16
0
PWM value 0 … 1000 HB0
5
set value PWM chan 24
rw
u16
0
PWM value 0 … 1000 HB1
6
set value PWM chan 25
rw
u16
0
PWM value 0 … 1000 HB2
7
set value PWM chan 26
rw
u16
0
PWM value 0 … 1000 HB3
20F0
0
CANopen node ID
rw
u8
0x20
1���127
20F1
0
CANopen node ID
rw
u8
0x20
The entries 20F0/20F1 must always
contain identical values�
The new entries are valid after a reset
(switching the module off/on)�
Values outside the permissible ranges
will be rejected�
20F2
0
CAN baud rate
rw
u8
0x04
0 = 1000 Kbaud
1 = 800 Kbaud
2 = 500 Kbaud
3 = 250 Kbaud
4 = 125 Kbaud
5 = 100 Kbaud
6 = 50 Kbaud
7 = 20 Kbaud
20F3
0
CAN baud rate
rw
u8
0x04
The entries 20F2/20F3 must always
contain identical values�
The new entries are valid after a reset
(switching the module off/on)�
Values outside the permissible ranges
will be rejected�
20F4
0
auto start
rw
u16
0x00
Time after reaching Preoperational State
to change to Operational State�
0���5000 ms
0 = auto start deactivated
6100
0
number of binary inputs (8bit)
ro
u8
0x01
1
binary inputs
ro
u16
-
bits 0…10: binary inputs 0���10
6200
0
number of binary outputs (8bit)
ro
u8
0x02
1
binary outputs
wo
u8
0x00
bits 0…6: binary outputs 0…7