12
8 Operating and display elements
9
10
11
SP
1
SP
2
10
3
°C
Mode/Enter Set
Nm
/s
Nm
3
Nm
3
/h
N
l/m
in
1 2 3 4 5 6 7 8
1 to 8: Indicator LEDs
-LED 1���6: process value in the indicated unit of measurement
-LED 7, LED 8: switching state of the corresponding output�
9: Alphanumeric display, 4 digits
- Current flow volume
- Current medium temperature
- Current consumed quantity (= meter reading)
- Consumed quantity (= meter reading) before the last reset
- Display of the parameters and parameter values
10: Mode/Enter button
- Selection of the parameters and acknowledgement of the parameter values�
11: Set pushbutton
- Setting of the parameter values (scrolling by holding pressed; incrementally by pressing
once)�
- Change of the display unit in the normal operating mode (Run mode)�
For units ≥ DN150 the displayed totaliser value has to be multiplied by the
factor 1000�