Factory setting
Display
• Red text colour
• Update of the measured values every 200 ms
• Standard display: flow
40).
4 Functions and features
The unit monitors gaseous media.
It detects the process categories flow and medium temperature.
4.1 Application area
• Medium = air
In applications > 6 bar (> 600 kPa), flow range inaccuracies may occur due
to the natural convection of the air.
This is a class A product. This product may cause radio interference in
domestic areas.
u
If required, take appropriate EMC screening measures.
5 Function
• The unit detects flow based on the calorimetric measuring principle.
• As additional process value the unit detects the medium temperature.
• The unit has an IO-Link interface.
• The unit displays the current process values.
• The unit has many self-diagnostic options.
• The unit generates two output signals according to the parameter setting.
5.1 Output OUT1 selection options
• Switching signal flow
• Frequency signal flow
• IO-Link
5.2 Output OUT2 selection options
• Switching signal flow
GB