CANopen encoder
24
Index S-Idx Name
Type,
access
default value
Description
6001
0
Measuring
units per
revolution
u32, rw
see
type label
Setting steps per revolution
6002
0
Total
measuring
range in
measuring
units
u32, rw
see
type label
Setting the total resolution of the
measuring range
6003
0
Preset value
u32, rw
0
Setting the preset value for the encoder
6004
0
Position value
u32,
romap
-
The object gets the position value
6030
Speed value
If the max� possible value is exceeded,
the value stops there� The user can use
the object 3010 (32 bits)�
0h
Number of sub
indices
u8, ro
1h
1h
Speed value
channel 1
integer
16, romap
-
6200
0
Event time
u16, rw
0x64
This object contains the value of the
event timer of the corresponding PDOs�
The value can be set between 1 and
65538 ms�
6300
Cam state
register
The object describes the cam state
register� The object contains the current
position of the cam from 1 to 8�
0h
Number of sub
indices
u8, ro
1h
1h
Cam state
channel 1
u8, romap 4h
6301
Cam enable
register
The object describes the cam state�
0h
Number of sub
indices
u8, ro
1h
1h
Cam enable
channel 1
u8, rw
6302
Cam polarity
register
The object describes the cam behaviour�
0h
Number of sub
indices
u8, ro
1h
1h
Cam polarity
channel 1
u8, rw
0h
List of cam objects