5.3 Use in hygienic areas to EHEDG
The sensor is suited for CIP (cleaning in process) when installed correctly�
►
Observe the application limits (temperature and material resistance)
according to the data sheet�
►
Make sure that the sensor is integrated into the system according to EHEDG:
►
Use self-draining installation�
►
Only use process adapters permitted according to EHEDG with special seals
required by the EHEDG position paper�
The gasket of the system interface must not be in contact with the
sealing point of the sensor�
►
In case of structures in a tank, the installation must be flush mount� If not
possible then direct water jet cleaning and cleaning of dead spaces must be
possible�
►
Leakage ports must be clearly visible and must be installed facing downwards
for vertical pipes�
1
D
L
►
To avoid dead space adhere to the
dimensions:
L < (D)�
1: Leakage port