11
UK
7 Operating and display elements
Mode/
Enter
Set
1
2
3
4
5
6
1: Analogue display
-Display of the current system pressure in mbar and kPa, bar and kPa or bar and MPa�
(→ Depending on the measuring range)
�
2: LED ring
According to the setting of parameter [LED]
-Display of set point and reset point�
-Lag indicator function for maximum value or minimum value�
-Display of pulsating signals and pressure peaks�
-Trend display: rising pressure or falling pressure�
3: Indicator LEDs
-LED 1 = system pressure of the digital display in bar/mbar�
-LED 2 = system pressure of the digital display in MPa/kPa�
-LED 3, LED 4, LED 5, LED 7 = not used�
-LED 6 = system pressure in % of the scaling (range ASP to AEP) or COF value in %�
-LED 8 = switching status OUT1 (on when output 1 is switched)�
4: Alphanumeric display, 4 digits
-Display of the current system pressure�
-Display of the parameters and parameter values�
5: Touch button Set*
-Setting of the parameter values (continuously by touching permanently; step by step by
touching briefly several times)�