Measuring light grids (10 mm beam spacing)
OY51
11
7 Electrical connection
u
Disconnect power. Also, disconnect any independently supplied relay load circuits.
The nominal voltage is 24 V DC; this voltage may vary between 19.2 V and 28.8 V.
In case of a single fault, the supply voltage must not exceed a maximum of 28.8 V DC.
Therefore, a safe separation between current supply and transformer is necessary.
To guarantee functional reliability an output capacity of min. 2000 µF / A has to be ensured if a
power supply with diode bridge is used.
u
Connect the devices as indicated in the following table:
7.1 Transmitter wiring diagram
Pin layout
Pin
Name
Type
Description
4
2
1
3
5
1
L+ (24 V DC)
-
Operating voltage
2
Range
Input
Configuration detection field width
24 V DC → range 1...10 m
0 V DC → range 0…2 m
3
L- (0 V DC)
-
Operating voltage
4
SYNC
Output
Synchronisation output
5
-
-
Not used
For information about available sockets/connectors see:
7.2 Receiver wiring diagram
Pin layout
Pin
Name
Type
Description
4
2
1
3
5
1
L+ (24 V DC)
-
Operating voltage
2
SYNC
Input
Synchronisation input
3
L- (0 V DC)
-
Operating voltage
4
Q
IEC 61131-3
Switching signal (SIO)
C
IEC 61131-9
IO-Link interface (COM1, COM2, COM3)
5
-
-
Not used
For information about available sockets/connectors see:
7.3 Synchronisation of transmitter and receiver
To ensure a reliable function of the measuring light grid, the transmitter and the receiver must be
synchronised. The two units can be synchronised optically Optical synchronisation (
cable Synchronisation via ifm Y cable (EY5053 and EY5054) (
11). The settings are made via
IO-Link.
7.3.1 Synchronisation via ifm Y cable (EY5053 and EY5054)
The transmitter and the receiver can be synchronised using ifm Y cables (EY5053 or EY5054). They
must be wired according to the figure.