OY51
Measuring light grids (10 mm beam spacing)
12
T
R
1
2
L
3
2
BN
BK
BU
1
L+
T:
Transmitter
R:
Receiver
1:
ifm Y cable
2:
Connection
Alternatively, the receiver can also be connected directly to the IO-Link master using a suitable
standard cable. The transmitter can be connected separately via a standard M12 connector (5-
pin). In this case, only optical synchronisation is possible Optical synchronisation (
12).
For long detection field widths (1...10 m range): EY5053
For short detection field widths (0...2 m range): EY5054
7.3.2 Synchronisation via standard sockets
L
SYNC
1 BN
2 WH
4 BK
3 BU
L+
2
L
IN
SYNC
1 BN
2 WH
4 BK
3 BU
L+
21
T
R
T:
Transmitter
R:
Receiver
1:
Connection transmitter
2:
Connection receiver
SYNC: Synchronisation
IN:
24 V DC
Ò
range 1…10 m
0 V DC
Ò
range 0…2 m
7.3.3 Optical synchronisation
The highest beam is used for optical synchronisation.