8
6.3 Setting of maximum sensitivity*
► Go into the programming mode of the unit. (→ step 1).
►
Align the sensor so that no light is reflected�
► Press the setting button twice (→ steps 2 and 3).
* The maximum sensitivity can also be set in exactly the same way using the programming
wire (pin 2 / WH). To activate the functions the programming wire is connected to L+ (pin 1 /
BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time.
6.4 Electronic lock
Activate the lock by connecting the programming wire for about 15 s -20 s*�
De-activate the lock by connecting the programming wire again for 15 s - 20 s*�
* To activate the functions the programming wire (pin 2 / WH) is connected to L+ (pin 1 / BN)
for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time.
6.5 Programming the output function*
►
Press for 10 s�
>
The red LED starts to flash fast after
2 s�
>
Then the yellow and green LEDs flash
alternately�
> After 10 s, all LEDs go off, the output
function has changed from light-on mo-
de to dark-on mode (or vice versa).
* The output function can be programmed in exactly the same way using the programming
wire (pin 2 /WH). To activate the functions the programming wire is connected to L+ (pin 1 /
BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time.