► Allow objects to pass through the detection area during the measurement (about
1 s) (number of the objects between min. 8 Hz and max. switching frequency).
►
Press once�
>
The yellow and green LEDs go out for approx. 1 s, then flash again alternately.
3
► Allow objects to pass through the detection area during the measurement (about
1 s) (number of the objects between min. 8 Hz and max. switching frequency).
►
Press once�
>
The yellow and green LEDs go out for approx. 1 s., after approx. 3 s the green
LED is on�
>
The unit is in the operating mode.
* The sensitivity can also be set in exactly the same way using the programming wire (pin 2 /
WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP
units or to L- (pin 3 / BU) for NPN units for the appropriate time. Feedback: If setting was not
successful via the programming wire, the output will switch for 2 s. The unit then passes into
the operating mode with the sensitivity being unchanged�
If the setting of the sensitivity is not possible (e.g. object signal and back
-
ground signal are about the same), the red LED flashes after step 3 for ap
-
prox. 2 s. The unit then passes into the operating mode with the sensitivity
being unchanged�
If the setting button is not activated for 15 minutes during the programming
process, the unit passes automatically into the operating mode with the
sensitivity being unchanged�