26
The sensor is aligned to the background�
The teach process sets [SP2] so that objects with a higher reflectivity
(brighter objects) are reliably detected against the background (if [ou2] =
[hno])�
Set point and reset point are set automatically
10.3.3 Teach the switch point for window function OUT1 / OUT2
►
In [OU1] / [OPU2], select the output function [Fno] or [Fnc]�
►
Confirm with [ENTER]�
►
Change to [EF]�
►
Select [tn1] / [tb2]�
> Parameter value for [nP1] / [bP2] is displayed�
►
Press the "up" or "down" button and keep it pressed�
> The parameter value flashes for 3 s�
> New parameter value is displayed�
►
Confirm with [ENTER]�
►
Select [tF1] / [td2]�
> Parameter value for [FP1] / [dP2] is displayed�
►
Press the "up" or "down" button and keep it pressed�
> The parameter value flashes for 3 s�
> New parameter value is displayed�
►
Confirm with [ENTER]�
ou1
tn1
tf1
np1
fp1
ou2
tb2
td2
bp2
dp2
10.3.4 Set switching hysteresis level for OUT2
►
Change to [EF]�
►
Select [HYL]�
►
Select [Lo] or [Hi] with the arrow keys�
►
Confirm with [ENTER]�
lo
xi
Lo: Small hystereses enable detection of smaller reflectivity differences�
This is the default setting�
Hi: Larger hystereses, to be used for difficult applications such as highly
reflective surfaces�
For information about hysteresis curves → data sheet.