8.3 Explanation of the menu
For the factory settings please refer to the end of these instructions
0v1
Configuration for output 1
5 switching functions can be selected:
[Hno], [Hnc], [Fno], [Fnc], [OFF]
→ 10.2.1 Configure OUT1 / OUT2
�
0v2
Configuration for output 2
5 switching functions can be selected:
[Hno], [Hnc], [Fno], [Fnc], [OFF]
→ 10.2.1 Configure OUT1 / OUT2
�
5p1
Switch point for hysteresis function OUT1
Limit at which the output with selected hysteresis function changes its
switching status (object nearer/farther than distance set)�
[SP1] is only active if [OU1] = [Hno] or [Hnc]
→ 10.2.5 Set the switch point for the hysteresis function OUT1 /OUT2
5p2
Switch point for hysteresis function OUT2
Value at which the output with selected hysteresis function changes its
switching status (object brighter/darker than reflectivity set)�
[SP2] is only active if [OU2] = [Hno] or [Hnc]
→ 10.2.5 Set the switch point for the hysteresis function OUT1 /OUT2
np1
fp1
Switch points for window function OUT1
Values at which the output with selected window function changes its
switching status (object present / not present between the distance "near" and
the distance "far")�
[nP1] = switch point "near" / [FP1] = switch point "far"�
[nP1/FP1] are only active if [OU1] = [Fno] or [Fnc]
→ 10.2.8 Set the switch points for window function OUT1 /OUT2.
�
bp2
dp2
Switch points for window function OUT2
Limits at which the output with selected window function changes its switching
status (object reflectivity between "bright" and "dark")�
[bP2] = switch point "bright" / [dP2] = switch point "dark"�
[bP2] / [dP2] are only active if [OU2] = [Fno] or [Fnc]
→ 10.2.8 Set the switch points for window function OUT1 /OUT2.
ef
Extended functions
Press [ENTER] to open the submenu "Extended functions"
re5
Restore the factory setting
→ 10.3.8 Reset all parameters to factory setting
�