8
2
►
Remove the object�
transmitter
receiver
►
Press [OUT off]�
> The sensitivity is set without object�
> The green LED lights, the yellow LED indicates the switching status�
> The programming is finished�
6.1.2 The sensor is not to switch when the object is detected
►
Position the object (see figure 1) and press [OUT off]�
►
Remove the object (see figure 2) and press [OUT on]�
The settings can also be carried out first without object (step 1) and then with
object (step 2)�
Timeout
If no button is pressed for 15 min during the setting procedure, the unit
changes to the normal operating mode with unchanged values�
6.1.3 Measured value difference too small
If the measured value difference is too small, the switching threshold can be
manually adjusted�
>
The unit changes to the manual setting mode. → 7.2 Manual setting of the
sensitivity / step 2�
6.2 Manual setting of the sensitivity
Carry out the automatic setting prior to the manual setting to determine the
light-on / dark-on mode�
Diffuse reflection optics (FT-50) / through-beam optics (FE-50)
1
►
Press [OUT off] for > 6 s to < 20 s�
> The green LED flashes with 2 Hz, the yellow LED indicates the switching status�
> The row of LEDs indicates the input signal strength and flashes to indicate the
switching threshold�