background image

3

UK

4 Installation

 

Fit the prismatic reflector or the reflective tape behind the object to be detected.

 

Align the retro-reflective sensor to it and secure it to a bracket.

Maximum range is only possible with precise alignment.

5 Operating and display elements

1:  LED

2:  [OUT on]

3: 

[OUT off]

6 Electrical connection

The unit must be connected by a qualified electrician.

 

The national and international regulations for the installation of 

electrical equipment must be adhered to.

 

Voltage supply according to EN 50178.

Содержание O5P7 Series

Страница 1: ...Operating instructions Retro reflective sensor O5P7xx 80284273 00 04 2019 UK ...

Страница 2: ...ed herein may result in hazardous radiation exposure Visible laser light CLASS 1 LASER PRODUCT EN IEC 60825 1 2007 and EN IEC 60825 1 2014 complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No 50 dated June 2007 Position of the product label Additional label 3 Functions and features In conjunction with a prismatic reflector or reflective tape the retro reflective sensor detec...

Страница 3: ...ure it to a bracket Maximum range is only possible with precise alignment 5 Operating and display elements 1 LED 2 OUT on 3 OUT off 6 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the installation of electrical equipment must be adhered to Voltage supply according to EN 50178 ...

Страница 4: ...or 2 s The sensitivity is set to the object The yellow LED flashes 2 Remove the object Press OUT off The sensitivity is set without object The yellow LED goes out The programming is finished 7 2 The sensor is not to switch when the object is detected Position the object see figure 1 and press OUT off Remove the object see figure 2 and press OUT on The setting can also be carried out first without ...

Страница 5: ...ceeded 7 5 Electronic lock Lock or unlock the buttons Press OUT on and OUT off simultaneously for 10 s Acknowledgement is indicated by a change of the LED status 8 Operation Check whether the unit operates correctly The LED lights when the switching output is switched 9 Maintenance repair and disposal Keep the front pane of the sensor free from soiling For cleaning do not use any solvents or clean...