background image

Object recognition sensor

O2D51x O2D53x

13

5.2 Mounting with clamp

2

1

3

4

Fig. 5: Installation using the mounting set E2D500

1:

M4 screws

2:

threaded M4 holes (depth 7 mm)

3:

bracket

4:

clamp

u

Fasten the bracket to the threaded M4 holes of the unit using two M4 screws. Tightening torque
max. 2.1 Nm.

u

Fix the clamp to the bracket.

Содержание O2D51 Series

Страница 1: ...Operating instructions Object recognition sensor O2D51x O2D53x Firmware 1 22 9009 or higher 11436819 00 01 2022 GB...

Страница 2: ...ernal debouncing 9 4 4 Switching output 10 4 5 Internal illumination 10 4 5 1 O2D51x 11 4 5 2 O2D53x 11 5 Mounting 12 5 1 Installation instructions 12 5 2 Mounting with clamp 13 5 3 Mounting with dome...

Страница 3: ...safety of devices with Risk Group 2 must be taken into consideration Device of protection class III Only for operation in PELV circuits chapter Electrical connection 1 4 Legal and copyright informati...

Страница 4: ...plied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU General Public License and the GNU Lesser General Public License for more details The responsibility of ifm electronic...

Страница 5: ...safety The device classification according to EN 62471 is based on a distance of the viewer from the light source of 200 mm for the most unfavourable device configuration colour exposure time frame ra...

Страница 6: ...r to equal that of Risk Group 1 or the Exempt Group RG 0 u When selecting the blue and white LEDs observe the distances between the light source and the eye specified in the following table LED red LE...

Страница 7: ...The device safety is rated for use under the following operating conditions according to EN IEC 61010 2 201 indoor use altitudes up to 4000 m relative air humidity up to max 90 non condensing polluti...

Страница 8: ...Parameter setting interface Ethernet TCP IP Integrated configurable contour verification and blob analysis Monitoring of the following object properties patterns and shapes inner and outer radius roun...

Страница 9: ...rent trigger modes can be used software manual at documentation ifm com Negative edge Positive edge Negative and positive edge Gated trigger Burst trigger During an active trigger process no new trigg...

Страница 10: ...ding devices in order to prevent mutual interference during image capture Error The unit signals an internal error Detailed information about errors can be requested via Ethernet Controlled via proces...

Страница 11: ...The optics of the device and two of the four LEDs are equipped with polarisation filters u Only activate the LEDs with polarisation filters to avoid direct reflection 4 5 2 O2D53x The device features...

Страница 12: ...the unit u Do not exceed the following limits Temperature Maximum recommended relative humidity 25 C 75 30 C 72 35 C 70 40 C 67 u Avoid back light scattered light and changing light conditions Sunlig...

Страница 13: ...clamp 2 1 3 4 Fig 5 Installation using the mounting set E2D500 1 M4 screws 2 threaded M4 holes depth 7 mm 3 bracket 4 clamp u Fasten the bracket to the threaded M4 holes of the unit using two M4 screw...

Страница 14: ...ing the mounting set E2D501 1 M4 screws 2 threaded M4 holes depth 7 mm 3 bracket 4 clamp 5 dome illumination u Fasten the bracket to the threaded M4 holes of the unit using two M4 screws Tightening to...

Страница 15: ...ctromechanical device Separate the circuit from other non energy limited circuits by at least basic insulation The separation of external circuits must comply with IEC 61010 2 201 figure 102 u Disconn...

Страница 16: ...the L coded connector may no longer be met u Check contacting on the cable and adjust if necessary 6 1 1 PNP NPN selection Pins 2 and 4 can be switched between PNP and NPN logic The setting cannot be...

Страница 17: ...trigger signal through to the external illumination unit Since the sensors with infrared light have a band pass filter only external illuminations with a wave length range between 780 nm 880 nm can be...

Страница 18: ...n the software manual Software manual at documentation ifm com 7 1 Update firmware u Download the ifmVisionAssistant software via the download area of the unit documentation ifm com If a certified fie...

Страница 19: ...8 Hz Error configuration failed Tab 4 Multifunction LED green yellow Ethernet LED Power LED OUT1 LED TRG LED Description Off On Off Off Unit is ready for operation flashes at 0 5 Hz No parameters set...

Страница 20: ...O2D51x O2D53x Object recognition sensor 20 means undefined state...

Страница 21: ...an be used below 0 C The possible ambient temperatures are specified in the data sheet After power on the unit is put into operation After approx 30 seconds the unit is in the evaluation mode where sa...

Страница 22: ...3 seconds w The green multi function LED is permanently on u Align the object to the centre of the sensor s optical axis u Press the multi function key for 1 second within 2 minutes timeout w The yell...

Страница 23: ...the front lens of the unit 1 u Observe the notes on installation Installation instructions 12 Only available for O2D51x devices 11 1 Over temperature protection To protect the hardware the unit is equ...

Страница 24: ...Troubleshooting If the unit behaves unexpectedly or incorrectly u Download and install the latest firmware and ifmVisionAssistant versions Download at documentation ifm com If the problems persist u C...

Страница 25: ...e of 55 C If this time is exceeded data loss is possible During operation the stored data is refreshed periodically The service lid may only be opened for the transfer of the configuration u Only open...

Отзывы: