Photoelectric distance sensor
O1D111
19
Current output 4...20 mA
Factory setting
Measuring range scaled
MEW: Final value of the measuring range
In the set measuring range the output signal is between 4 and 20 mA.
Faults are also displayed:
Too much light or object too near: 3.5 mA for a rising edge ([ASP] < [AEP]), 20.5 mA for a falling edge
([ASP] > [AEP]).
Object too far or no object present:
20.5 mA for rising edge. 3.5 mA for falling edge.
Voltage output 0...10 V
Factory setting
Measuring range scaled
MEW: Final value of the measuring range
In the set measuring range the output signal is between 0 and 10 V.
10.3 Teach mode
10.3.1 Setting of the sampling rate
The sampling rate indicates the maximum time after which a new result of measurement is provided
and the outputs are updated. The switching frequency is typ. approx. 1/3 of the sampling rate.
u
Select [TEAC] and keep [SET] pressed until [WAIT] is displayed.
w
[rATE] and [rEPr] are displayed alternately.
u
If [rATE] is displayed: Press [SET] until the preset sampling rate value flashes.
u
Enter a value incrementally by pressing [SET] repeatedly.
u
Confirm with [MODE/ENTER].