CR3156
mobileIoT gateway
22
Function
Index
Subindex
Description
Revert to factory configuration 0x1011
0x01
The factory configuration is restored. All recorded data is de-
leted.
Delete all log files
0x1011
0x62
All recorded data is deleted.
Revert to firmware defaults
remote
0x1011
0x63
The default configuration of the current firmware is restored.
All recorded data is deleted.
CAN, WLAN, Bluetooth and mobile radio settings as well as
the factory configuration are retained.
Revert to firmware defaults
plus format remote
0x1011
0x64
The default configuration of the current firmware is restored.
All recorded data and the factory configuration are deleted.
CAN, WLAN, Bluetooth and mobile radio settings are re-
tained.
Revert to firmware defaults lo-
cal
0x1011
0x65
The default configuration of the current firmware is restored.
All recorded data and settings are deleted.
The factory configuration is retained.
To carry out the factory reset via the CAN interface, CANopen software (e.g. maintenance tool) and a
communication gateway (e.g. CANfox, part no. EC2112) are required. The CANopen software writes
the value 0x64616F6C into the CANopen object index 0x1011 to trigger a specific reset variant.
The following example shows the factory reset via the sub-index 0x65 (restoration of the default
configuration):
u
Connect the unit with a PC. Connect the unit (
u
Start the CANopen software.
u
Write the value 0x64616F6C into the object index 0x1011, subindex 0x650 via the CANopen
software.
u
Write the value to the object dictionary of the unit.
u
Wait until the unit sends the CANopen boot-up message on COB-IDs 0x727 and 0x728.
w
The unit is reset to the firmware default settings (object 0x1011 0x65).
w
The ON LED lights green.
w
The STATUS LED lights blue.
w
The unit has adopted the firmware defaults (baud rate 250 kbit/s, node ID 39 etc.).