12 Factory setting
Parameter
Factory setting
User setting
Access
Application Specific Tag
***
Function Tag
***
Location Tag
***
uni
m
Reference height
Initial value
Tank offset
0 (m)
Upper blind zone
0 (m)
P-n
PnP
out1/out2
SSC1 / I (4…20 mA)
dS1/dS2
0 (s)
dr1/dr2
0 (s)
SSCx* Param. SP1
0.2 (m)
!
SSCx* Param. SP2
0 (s)
!
SSC* Confic. Logic
no
SSC* Confic. Mode
Single point
SSC* Confic. Hysteresis
0.05 (m)
!
ASP2
0 (m)
!
AEP2
0.2 (m)
!
FOU2
OFF
dAP
2 (s)
S.Lvl
5 (m)
S.Tim
60 (min)
Alert mode delay time
180 (s)
Detection threshold
100 (mV)
*x = 1 for OUT1, 2 for OUT2
Parameters marked with “!” (under Access) (e.g. [SSCx* Param. SP2]) are only active if the
assigned parameters have been selected.