12
5.6.3 Filling edge sharpness
Relates to the sharpness of the edge of the level in a value range from 0 to 100� If
no edge of the level could be detected, the substitute value "0xFF" is provided� A
low value can for example indicate an uneven filling edge�
High edge sharpness
Low edge sharpness
2
1
2
1
2
1
Fig� 3: Representation of the edge sharpness
1: Tank wall
2: Medium
If the edge sharpness is too low, it may not be possible for the sensor to correctly
detect the level�
The edge sharpness can only be determined if the medium to be detected
is within the measuring range of the unit�
5.6.4 Installation quality
Relates to the installation quality in a value range of 0-100� If there is full
adjustment a value estimated by the unit is provided� A low value may for example
indicate metal parts that are too close to the sensing face of the sensor
5.7 Internal temperature
The internal temperature of the unit can be read
�
Minimum value and maximum value are cyclically stored in the memory of the
unit� The values can be used for orientation after a new start of the unit�