UK
Inclination sensor JN
21
5-bit FMI -> 4
1-bit CM -> 0 (always 0)
7-bit OC -> 1
12 Status LED
The integrated LED indicates the current device state.
LED colour
Flashing frequency
Description
green (left connector)
permanently on
The device is in the "run" state
red (right socket)
permanently on
MEMS self-test failed
13 Maintenance, repair and disposal
The unit is maintenance-free.
► Dispose of the device in accordance with the national environmental
regulations.
14 Approvals/standards
The CE declarations of conformity and approvals can be found at www.ifm.com.
14.1 Reference to UL
The external supply source and external circuits intended to be connected to this
device shall be galv. separated from mains supply or hazardous live voltage by
reinforced or double insulation and meet the limits of clauses 6.3 Limit values for
accessible parts and 9.4 Limited energy circuit of UL 61010-1.
Minimum temperature rating and size of the cable to be connected to the field
wiring terminals, min. 75°C, min. 22 AWG or 0.34mm².
15 Factory setting
Index
Type
Value
Delivery
0x1100
u8
TxPGN1 active
1: is sent cyclically
0x2000
u8
Device address
25
0x2001
u16
Baud rate
250 Kbits
0x2040
u8
Flag for quadrant correction
1: corresponds to +/-180°
0x2041
u8
Flag for heating
1: corresponds to "heating on"
0x2042
u8
Index teach value of the X/Y/Z axes
2: corresponds to "absolute measurement"
0x2043
u8
FIR filter step
2: corresponds to "FIR lowpass 5Hz"