Setting of the sensitivity with stationary objects
You can also proceed in reverse order: first setting without the object,
then with the object.
If the setting of the sensitivity is not possible (e.g. object
signal and background signal are about the same), the LED flashes
after step 3 for approx. 2s. The unit then passes into the operating
mode with the sensitivity being unchanged.
8
Press for about 2s until the LED flashes.
Activate the programming mode of the unit.
The LED starts to flash rapidly. The unit is in the programming mode
as soon as the LED flashes slowly
1
Set the sensitivity
with
object.
Press once.
The LED goes out during the first measuring process. As soon as the
LED flashes slowly, the unit is in the programming mode again.
2
Press once.
The LED goes out during the second measuring process.
If the programming was successful, the unit is now in the
normal operating mode.
3
Set the sensitivity
without
object.
receiver
transmitter
receiver
transmitter
receiver
transmitter