5  Electrical connection

The unit must be connected by a qualified electrician.

 

► The national and international regulations for the installation of electri-

cal equipment must be adhered to.

 

► Ensure voltage supply to EN 50178.

 

► Disconnect power.

 

► Connect the unit as follows:

5.1  Transmitter

Connector M12 pigtail

Cable *

 

1

3

L+

L

Connector M8 3-pin

Connector M8 4-pin

 

1

3

L+

L

2

1

4

3

  

1

3

L+

L

* Core colours:  BN = brown, BU = blue, BK = black

5.2  Receiver
5.2.1  PNP

Connector M12 pigtail

Cable *

 

Connector M8 3-pin

Connector M8 4-pin

 

2

1

4

3

  

* Core colours:  BN = brown, BU = blue, BK = black

Содержание Efector 200 O6E3

Страница 1: ...Operating instructions Through beam sensor O6E3 O6S3 O6E3IO 00 01 2015 UK ...

Страница 2: ...result in malfunctions or interference 2 Functions and features The through beam sensor detects objects and materials without contact and indicates their presence by a switching signal 3 Installation Transmitter Receiver Install the receiver O6E and secure it to a bracket Align the transmitter O6S to the receiver and fix it Maximum range only with accurate alignment ...

Страница 3: ...Selector output function Receiver 4 1 Stability indication The green LED on the receiver is lit when the supply voltage is applied and there is sufficient excess gain Under these conditions the sensor receives a stable signal stable signal switch point stable signal Light on mode LED green on off off on LED yellow on on off off Dark on mode LED green on off off on LED yellow off off on on ...

Страница 4: ...adhered to Ensure voltage supply to EN 50178 Disconnect power Connect the unit as follows 5 1 Transmitter Connector M12 pigtail Cable 1 3 L L Connector M8 3 pin Connector M8 4 pin 1 3 L L 2 1 4 3 1 3 L L Core colours BN brown BU blue BK black 5 2 Receiver 5 2 1 PNP Connector M12 pigtail Cable Connector M8 3 pin Connector M8 4 pin 2 1 4 3 Core colours BN brown BU blue BK black ...

Страница 5: ... 3 Core colours BN brown BU blue BK black 6 Settings 6 1 Set the output function D L Setting D dark on mode Setting L light on mode Receiver 6 2 Set the sensitivity Increase sensitivity turn the setting screw of the potenti ometer clockwise Decrease sensitivity turn the setting screw of the potenti ometer anti clockwise Receiver ...

Страница 6: ...or values and parameters and provides the possibility to set the parameters of the unit during operation In addition communication is possible via a point to point connection with a USB adapter cable You will find more detailed information about IO Link at www ifm com uk io link 8 2 Device specific information You will find the IODDs necessary for the configuration of the IO Link unit and detailed...

Страница 7: ... any solvents or cleaning agents which could damage the plastic parts After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations Faulty sensors must only be repaired by the manufacturer Technical data and further information at unter www ifm com ...