![IFM Efector 180 IX5030 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ifm/efector-180-ix5030/efector-180-ix5030_operating-instructions-manual_3873892008.webp)
8
Ensure a tight and secure fit�
Make sure that no metallic components
are in the immediate vicinity of the
sensor or approach the sensor during
operation (especially no metal rings which
enclose the sensor)! This might affect the
functioning of the sensor�
Fixing elements such as screws, clamps
and similar small metal parts (< 20 x 20 x
30 mm) have no impact on the sensor� For
safe functioning the adapter (3) must be
made of plastic�
A = metallic objects
x = min� 10 mm
y = min� 46�5 mm
5 Electrical connection
The unit must be connected by a qualified electrician� The national and
international regulations for the installation of electrical equipment must be
adhered to�
Disconnect power before connecting
the unit as follows:
AS-i+
1
3
AS-i
5.1 Assignment of the data bits
Data bit
D0
D1
D2
D3
Description
close
seat
open
not used
state = 0
plunger outside
the 'close' zone
plunger outside
the 'seat' zone
plunger outside
the 'open' zone
default value
state = 1
plunger inside
the 'close' zone
plunger inside the
'seat' zone
plunger inside
the 'open' zone
-
Содержание Efector 180 IX5030