ecomatPanel (CR1300 / CR1301)
7
Wrong connection may cause damage to the unit�
►
Observe the safety instructions�
The short-circuit / reverse polarity protection of the unit applies to the
operating voltage connections�
►
Basically lay all supply and signal cables separately�
►
Lay supply and signal cables away from the device using the shortest possible
route�
►
All connected cables must be provided with a strain relief�
6.2.1 Cover all unused connectors
Moisture penetrating through unused or unprotected connectors may
destroy the unit�
►
Cover unused connectors with protective caps�
6.3 Fuses
►
To protect the unit use fuses for the operating voltages�
Designation
Potential
Connector 1 Fuse
Operating voltage
9…32 V DC
Pin 4
max� 2 A
Terminal designation to DIN 72552
6.4 Operating voltage and CAN interface
Tyco MQS connector (4-pole)
Pin
Potential
4
1
3
2
CAN interface
1
CAN_L
2
CAN_H
Operating voltage
3
GND
4
9…32 V DC
CAN Interface: 2�0 A/B, ISO 11898; Default 250 kbit/s
CAN protocol: SAE J1939