5
u
Carefully remove the protective cover.
u
Remove the battery compartment cover by pulling it downwards.
u
Insert 3x 1.5 V batteries or rechargeable batteries with the poles in the direction
marked.
u
Place the cover back on the battery compartment.
u
Refit the protective cover.
5 Electrical connection
Connect the sensor to be tested to the colour-coded quick-press terminals as
follows:
L
BU
WH
BK
BN
L+
OUT
Teach
BK:
black
BN:
brown
BU:
blue
WH:
white
(Colours to DIN EN 60947-5-2)
Do not use a connection cable with integrated LED.
6 Operation
Test the connected sensor at the corresponding test surfaces of the unit.
• [Magnet] for sensors with magnetic operating principle
• [Reflection] for retro-reflective sensors
• [Induction] for sensors with inductive operating principle
6.1 Teach function
Test units with remote teach function by pressing the [Teach] button.