5 Installation
u
Disconnect the power of the machine before installation.
u
For installation choose a flat mounting surface.
1
18
40
M4
Fig. 1: Fixture (view from bottom)
1:
Front side
u
Attach the fixture for the device to the mounting surface using the supplied M4 nuts. Tightening
torque 1.8 Nm.
u
Only with the models DV2900 and DV2910:
For mounting on a horizontal surface attach the base to the fixture (overlapping marks on base and
fixture) and turn clockwise by approx. 10 ° to fix it. For mounting on a vertical surface loosen the
screw in the base, turn the upper part of the base by 180 ° and tighten the screw again. Attach the
base to the fixture (overlapping marks on base and fixture) and turn clockwise by approx. 10 ° to fix
it.
u
Insert the cable through the fixture and, if necessary, the base and connect the socket with the M12
connector in the signal lamp. Tightening torque max. 0.4 Nm. (Observe the maximum tightening
torque of the connection cables.)
u
Attach the signal lamp to the fixture or the base (overlapping marks) and turn clockwise by approx.
10 ° to fix it.
Integrated seals at the bottom of the fixture and in the base as well as O-rings at the fixture and
base prevent ingress of moisture.
Information about available accessories at www.ifm.com