9
UK
7.1.2 On/off mode
While the unit is operating, the controller switches the LED segment and the
buzzer (DV213x) on and off (PDout, cyclical data communication). The signalling
corresponds to the parameters previously defined for the LED segment and the
buzzer�
Via acyclic parameter setting, the following properties can be set for the LED
segment:
•
Colour (red, green, orange, blue, violet, turquoise, white, yellow, off)
• Frequency (permanently on, low flash rate slow/medium/fast, high flash rate
slow/medium/fast)
•
Brightness (0...100 %)
For the models with an acoustic signal device the audibility of the buzzer can be
set�
7
6
5
4
3
2
1
0
PDOut
LED-c
LED-b
LED-a
Byte 0
Buzzer
Byte 1
7.1.3 RGB mode
While the unit is operating, the controller switches the LED segment and the
buzzer (only DV213x) on and off and determines the corresponding properties
(PDout, cyclical data communication).
In this operating mode, 8 different acoustic signals are available for the buzzer�
7
6
5
4
3
2
1
0
PDOut
LED properties
Seg� 1 =
yellow
Seg� 1 =
red
Seg� 1 =
green
Seg� 1
blue
Byte 0
Buzzer sound (buzzer style
1...8)
Buzzer
Byte 1