10 Maintenance, repair and disposal

The unit is maintenance-free.

u

Contact ifm in case of malfunction.

u

Do not open the housing as the unit does not contain any components which can be maintained by
the user. The unit must only be repaired by the manufacturer.

u

Clean the device using a dry cloth.

u

Dispose of the unit in accordance with the national environmental regulations.

Содержание DTI515

Страница 1: ...Operating instructions RF identification system DTI515 DTI516 Read write head 11453839 00 04 2022 GB...

Страница 2: ...nection 12 6 1 Wiring 12 7 Operating and display elements 13 8 Parameter setting 14 8 1 Parameter 14 8 1 1 Data block size 14 8 1 2 Data alignment 14 8 1 3 Data hold time 14 8 1 4 Address for automati...

Страница 3: ...ss reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright in...

Страница 4: ...nded purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty f...

Страница 5: ...DTI515 DTI516 5 3 Intended use The read write head reads and writes ID tags without contact The data is made available as process data via the IO Link interface...

Страница 6: ...orts ID tags according to ISO 15693 4 2 Device overview Article number DTI515 DTI516 Function Read write head Type designation DTRHF KQRWIOUS03 Type Rectangular 4 3 IO Link This unit has an IO Link co...

Страница 7: ...with a frequency of 13 56 MHz Avoid interference with data communication u Do not operate any devices in the vicinity that use the same frequency band w Such devices are for example frequency convert...

Страница 8: ...he upper edge of the device 1 into the mounting adapter u Insert the lower edge of the device 2 into the mounting adapter The device can be inserted into the mounting adapter E12153 in both directions...

Страница 9: ...evice with mounting adapter on the pipe The mounting adapter for pipes is available as accessory article number E12163 Fig 4 Installation with cable ties u Pull the cable ties through the openings of...

Страница 10: ...ading and writing 160 mm 170 mm 5 8 Positioning of the ID tags The sensing face marks the centre of the integrated antenna coil of the read write head u Align the sensing face of the read write head a...

Страница 11: ...11 D Fig 6 Position the ID tag u Align the ID tag on the central axis of the antenna of the device w The distance D is indicated in the data sheet The indications in the table apply to static read wri...

Страница 12: ...III The electrical supply must only be made via PELV SELV circuits u Disconnect power before connecting the device 6 1 Wiring u Connect the device to an IO Link master using the M12 connector w Voltag...

Страница 13: ...age OK Off Operating voltage missing Flashing slowly deactivated yellow On permanently ID tag detected On pulse ID tag read written successfully Flashing quickly Error when reading writing on ID tag O...

Страница 14: ...ignment The parameter sets the order of the data in a data block of the ID tag Example For an ID tag with block size 4 bytes the data can be ordered as in the tables Data block 0 Data block 1 Byte 3 B...

Страница 15: ...and written The length is indicated in bytes The minimum length is 1 byte and the maximum length is 29 bytes In the operating modes Auto read and Auto write the device reads and writes a specified num...

Страница 16: ...on not acknowledged 1 Start of a read or write operation acknowledged Cmd Antenna deactivate 0 Activate antenna 1 Deactivate antenna Cmd Start 0 Reset trigger for read or write operation 1 Set trigger...

Страница 17: ...next to each other is reduced by deactivating the antenna Deactivate the internal antenna u Set the Cmd Antenna deactivate bit in the process data output The status of the internal antenna is queried...

Страница 18: ...length of 29 bytes the data remaining in the process image is filled with the value 0x00 The data in the process image is updated as soon as an ID tag enters the detection range The data in the proces...

Страница 19: ...ta In the operating mode Auto write data the data to be written is defined by the process data output image The data is set with the parameters Address for Auto Read Write and Data Length for Auto Rea...

Страница 20: ...ta 3 6 Data 4 Data 4 7 Data 5 Data 5 8 Data 6 Data 6 9 Data 7 Data 7 10 Data 8 Data 8 11 Data 9 Data 9 12 Data 10 Data 10 13 Data 11 Data 11 14 Data 12 Data 12 15 Data 13 Data 13 16 Data 14 Data 14 17...

Страница 21: ...t two steps are repeated until all data has been transferred w The device sets the status bit Cmd End with the last transfer The read operation is terminated If reading was unsuccessful the device set...

Страница 22: ...e data 0x03 0x0012 0x0023 0x00 0x00 1 Controller ac knowledges re ceipt of the data 0x03 0x0012 0x0023 0x00 0x01 1 Device sets more data and terminates read ing 0x03 0x0012 0x0023 0x00 0x01 1 Controll...

Страница 23: ...ccessful Command value Address Length Data 0 to 27 Block counter Status bit Cmd Start Preset com mand 0x00 0x0000 0x0000 0x00 0x00 0 Controller sets command read 35 bytes from address 0x12 0x03 0x0012...

Страница 24: ...ess 16 bits and the data length 16 bits u With the control start the write operation with the status bit Cmd Start w The device acknowledges the start of the write operation by setting the status bit...

Страница 25: ...0x00 20 ignored Data 18 0x00 21 ignored Data 19 0x00 22 ignored Data 20 0x00 23 ignored Data 21 0x00 24 ignored Data 22 0x00 25 ignored Data 23 0x00 26 ignored Data 24 0x00 27 ignored Data 25 0x00 28...

Страница 26: ...Status bit Cmd End Status bit Cmd Start Preset com mand 0x00 UID 0x00 0x00 0 0 Controller sets command write 40 bytes to ad dress 0x10 0x04 UID 0x00 0x00 0 0 Device acknowl edges com mand 0x04 0x00 0...

Страница 27: ...0x02 1 Controller with draws com mand value 0x00 0x0000 0x0000 0x00 0x00 0 Device carries out preset com mand 0x00 0x0000 0x0000 0x00 0x00 0 Tab 9 Process data output Command value Data 0 to 27 Block...

Страница 28: ...ing reception of the data of the ID tag 0x21 TAG_COMMAND_NOT_SPECIFIED Command is not supported by the ID tag 0x22 TAG_COMMAND_SYNTAX Parameter of the command wrong 0x23 TAG_OPTION_NOT_SUPPORTED ID ta...

Страница 29: ...n case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device us...

Страница 30: ...or approvals and standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant f...

Страница 31: ...non volatile memory IODD Digital description of the device The IODD is required for device parameter setting via IO Link IO Link IO Link is a standardised IO technology IEC 61131 9 for communicating...

Отзывы: