6.7 Positioning of the ID tags
D
►
Align the ID tag on the
antenna central axis�
> Distance D see data
sheet
ID tags can also be read behind the unit� Should such cases occur despite
mounting precautions, the RSSI filter is recommended for suppression�
7 Electrical connection
NOTE!
The unit must be connected by a qualified electrician�
Device of protection class III (PC III)
The electric supply must only be made via SELV circuits�
►
Disconnect power before connecting the device�
►
For cable lengths > 30 m use an additional protection against surge
voltages to IEC 61000-4-5�
NOTE!
The IP rating indicated in the data sheet is only guaranteed if the M12
connectors are firmly screwed�
The device can be damaged by insufficiently tightened M12 connectors�
►
Screw the M12 connector to the device applying 1 to 1�5 Nm�