52
Request element "datatoset"
Value
Remark
dte/temperature_unit
0 = [°C]
1 = [F]
For DTEx05 valid
port
1 = IO-1
2 = IO-2
3 = IO-3
4 = IO-4
For DTEx05 valid
For DTEx05 valid
For DTEx05 valid
Only for DTE105 valid
mode
0 = RFID
1 = INPUT
2 = OUTPUT
3 = OFF
For DTE605,DTE805,DTE9x5 fix set on IO-1
data_hold_time
nn
[ms]
nn = { 0, 20, 40, 60, 80, 100, 200, 400, 600,
800, 1000, 1200, 1400, 1600, 1800, 2000}
/id_tag_config/block_size
BS
[bytes]
Only for DTE105 und DTE605 valid
HF ID tags: {4,8,16,32,64,128}
/id_tag_config/number_of_blocks
NoB
[bytes]
Only for DTE105 und DTE605 valid
HF ID tags: {1…256}
/overload_detection_enable
0 = off
1 = on
Only for DTE105 valid on IO-1 … IO-4
/overcurrent_detection_enable
0 = off
1 = on
Only for DTE105 valid on IO-1 … IO-4
/highcurrent_detection_enable
0 = off
1 = on
Only for DTE105 valid on IO-3 … IO-4
Response data:
{
"cid":4711, "adr":"//","code":200
}
Response
element
Value
Remark
cid
100
-
adr
"//"
The ‘data’ string element is coded in
Base64.
code
200
Response code of the IoT core
(2)
See chapter ->