12
Reset to factory settings
The Ethernet parameters and the password of the device can be reset to the factory settings. Take the
following steps:
►
Remove all cable connections from the device.
►
Insert an electrically conductive bridge between pin 2 and pin 4 on the process connection voltage supply
PWR.
►
Connect the unit to the voltage supply.
The LEDs of the signal bar (yellow) are on one after the other. Then LED 4 of the signal bar (yellow)
flashes at 8 Hz.
►
As soon as the LEDs of the signal bar (yellow) flash at 8 Hz, disconnect the unit
►
Remove the bridge.
►
Connect the device to the voltage.
►
The settings are reset.