DTE601 DTE602 DTE604 DTE605
RFID compact unit
18
LED red
LED green
State
Note
off
on
Normal operation
Connection to the EtherNet/IP scanner is
established. The device is configured. The
data transfer is running.
flashes
off
Minor error
A connection to the EtherNet/IP scanner
was not established:
u
Verify voltage supply.
u
Check the configuration of the unit.
on
off
Major error
Software / hardware error of the device:
u
Reboot the device.
w
If the error remains, send the device
for service.
flashes
flashes
Self-test
Starting phase of the device.
LED Net (network status)
LED red
LED green
State
Note
off
off
No IP address or no voltage supply
u
Verify voltage supply.
u
If DHCP is activated, check the
accessibility of the DHCP server.
off
flashes
No connection
The device has received an IP address.
An EtherNet/IP connection was not estab-
lished.
u
Check the configuration of the device
via EtherNet/IP scanner.
off
on
Connection exists
At least one EtherNet/IP connection to the
device was established.
flashes
off
Timeout of the connection
A timeout was found with one of the exist-
ing EtherNet/IP connections.
u
Check the status of the connection in
the EtherNet/IP scanner.
on
off
The IP address already exists
The same IP address as that of the device
was detected in the EtherNet/IP network.
u
Activate DHCP.
flashes
flashes
Self-test
Starting phase of the device.
8.3 Display elements DTE604 / DTE605
The following tables only apply to the DTE604 / DTE605 devices.
LED SF
LED red
LED green
State
Note
off
off
No voltage supply
Verify voltage supply.
off
on
Normal operation
-
flashes
off
Error at channel level
• Overload
• Temperature
• Internal error
on
off
Error at device level
• Undervoltage
• Temperature
flashes
flashes
Self-test
Starting phase of the device.
LED BF
LED red
LED green
State
Note
off
off
No voltage supply
Check the voltage supply