14
11 Technical data
Operating voltage DC
[V]
18...30
Nominal voltage DC
[V]
24
Current consumption
[mA]
300
Number of analogue outputs
2
Analogue output (voltage)
[V]
0...10
Extended voltage range
[V]
0...11
Min. load resistor
[Ω]
2000
Accuracy
[% FS]
0.25
Protection rating
IP 67*
Degree of soiling
2
Ambient temperature
[°C]
-25…70
Storage temperature
[°C]
-25…70
Max. perm. relative humidity
[%]
90 (31 °C)
linearly decreasing to 50 (40 °C)
non condensing
Maximum operating altitude
[m]
4000 above sea level
Connectors
M12 connector, 4-pole
M12 socket, 5-pole
*) With threaded M12 connectors tightened as described
IP class was not evaluated by UL.
11.1 IO-Link device
Transmission type
COM2 (38.4 kbaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
IO-Link device ID
614 d / 00 02 66 h
SIO mode
no
Required master port type
A/B
Process data analogue
OUT: 2
Process data binary
0
Min. process cycle time
[ms]
3.6