Programming Manual BasicDisplay CR0452 v03.02
05 / 2018
Configurations
Set up the programming system
>
Set up the target
13136
11379
When creating a new project in CODESYS the target file corresponding to the device must be loaded.
► Select the requested target file in the dialogue window [Target Settings] in the menu
[Configuration].
>
The target file constitutes the interface to the hardware for the programming system.
>
At the same time, several important libraries and the PLC configuration are loaded when selecting
the target.
► If necessary, in the window [Target settings] > tab [Network functionality] > activate [Support
parameter manager] and / or activate [Support network variables].
► If necessary, remove the loaded (3S) libraries or complement them by further (ifm) libraries.
► Always complement the appropriate device library
ifm_CR0452_Vxxyyzz.LIB
manually!
8485
NOTE
The software versions suitable for the selected target must always be used:
• runtime system (
ifm_CR0452_Vxxyyzz.RESX
),
• PLC configuration (
ifm_CR0452_Vxx.CFG
),
• device library (
ifm_CR0452_Vxxyyzz.LIB
) and
• the further files.
V
xx: 00...99
yy: 00...99
zz: 00...99
version
target version number
release number
patch number
The basic file name (e.g. "
CR0452
") and the software version number "xx" (e.g. "
01
") must always have
the same value! Otherwise the device goes to the STOP mode.
The values for "yy" (release number) and "zz" (patch number) do
not
have to match.
4368
The following files must also be loaded:
• the internal libraries (created in IEC 1131) required for the project,
• the configuration files (
*.CFG
) and
• the target files (
*.TRG
).
It may happen that the target system cannot or only partly be programmed with your currently
installed version of CODESYS. In such a case, please contact the technical support department of