ifm function elements
ifm function elements for the device CR0452
>
Parameters of the inputs
3293
Parameter
Data type
Description
INIT
BOOL
TRUE (only for 1 cycle):
Display is initialised with the initisalisation indicated in
INIT_PAGE.
FALSE:
during further processing of the program
INIT_PAGE
WORD
visualisation number which is to be called with INIT
PAGE_UP
BOOL
edge FALSE
TRUE:
increments the visualisation number
PAGE_DOWN
BOOL
edge FALSE
TRUE:
decrements the visualisation number
PAGE_EXTERN
WORD
The indicated visualisati→ p. is directly opened (independent of
PAGE_UP / PAGE_DOWN).
if PAGE_EXTERN = ACT_PAGE, then PAGE_EXTERN is
reset "0"!
PAGE_MAX
WORD
maximum number of selectable visualisation pages
BASENAME
STRING [35]
Common part of the name of the visualisati→ p. Visualisation pages
are numbered by their names: eg. P00001. The following applies:
• "P" = BASENAME (only capital letters!)
• "00001" = visualisation number (5 digits!)
>
Parameters of the outputs
3295
Parameter
Data type
Description
ACT_PAGE
WORD
current visualisation number