2 Safety instructions

General

The unit described is a subcomponent for integration into a system.

– The system architect is responsible for the safety of the system.

– The system architect undertakes to perform a risk assessment and to create documentation in

accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.

Read this document before setting up the product and keep it during the entire service life.

The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.

Only use the product for its intended purpose (

Ò

 → Intended use).

If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.

The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.

Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.

Protect units and cables against damage.

Radio equipment

In general, radio equipment must not be used in the vicinity of petrol stations, fuel depots, chemical
plants or blasting operations.

u

Do not transport and store any flammable gases, liquids or explosive substances near the unit.

Interference of electronic and medical devices

Operation can affect the function of electronic devices that are not correctly shielded.

u

Disconnect the device in the vicinity of medical equipment.

u

Contact the manufacturer of the corresponding device in case of any interference.

Содержание ANT515

Страница 1: ...Operating instructions RF identification system ANT515 ANT516 Read write head 11456779 00 04 2022 GB ...

Страница 2: ...ion 7 5 2 Avoiding interference 7 5 3 Mechanical design 7 5 4 Installation of the device with the mounting adapter on tanks 7 5 5 Installation of the device with mounting adapter on the pipe 9 5 6 Installation of the device without mounting adapter 10 5 7 Mounting distances 10 5 8 Positioning of the ID tags 10 6 Electrical connection 12 6 1 Wiring 12 7 Operating and display elements 13 8 Maintenan...

Страница 3: ...oss reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright information All rights reserved by ifm electronic gmbh No part of these instructions may be reproduced and used without the consent of ifm electronic gmbh All product names pictures companies or other ...

Страница 4: ...nded purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the product must be carried out by qu...

Страница 5: ... use The read write head reads and writes ID tags without contact For use the read write head must be connected to the DTE10x evaluation unit The data is converted into digitally coded values and provided to the evaluation unit ...

Страница 6: ...ve coupling The integrated antenna coil in the read write head generates a magnetic field which partly penetrates the antenna coil of the ID tag A voltage is generated by induction that supplies the data carrier with energy The device supports ID tags according to ISO 15693 4 2 Device overview Article number ANT515 ANT516 Function read write head Type designation DTRHF KQRWIDUS03 Type rectangular ...

Страница 7: ...d with a frequency of 13 56 MHz Avoid interference with data communication u Do not operate any devices in the vicinity that use the same frequency band w Such devices are for example frequency converters and switched mode power supplies If there are other devices in the same frequency band in the vicinity u The mounting distances between the devices should be as large as possible u Use the device...

Страница 8: ...the upper edge of the device 1 into the mounting adapter u Insert the lower edge of the device 2 into the mounting adapter The device can be inserted into the mounting adapter E12153 in both directions 3 Fig 2 Attach the device to the mounting adapter 3 Screws u Use the enclosed screws 3 to attach the device to the mounting adapter ...

Страница 9: ...device with mounting adapter on the pipe The mounting adapter for pipes is available as accessory article number E12163 Fig 4 Installation with cable ties u Pull the cable ties through the openings of the mounting adapter u Secure the device with cable ties to a pipe Metal cable ties may influence the degree of efficiency of the sensor u Use plastic cable ties ...

Страница 10: ...eading and writing 160 mm 170 mm 5 8 Positioning of the ID tags The sensing face marks the centre of the integrated antenna coil of the read write head u Align the sensing face of the read write head and the ID tag in the same way For installation in or on metal use the ID tags provided for this purpose Position the ID tag in the area of the sensing face When doing so the angle of aperture and the...

Страница 11: ... 11 D Fig 6 Position the ID tag u Align the ID tag on the central axis of the antenna of the device w The distance D is indicated in the data sheet The indications in the table apply to static read write operations ...

Страница 12: ...ower before connecting the device 6 1 Wiring u Connect the unit to a DTE10x evaluation unit via the M12 connector w Voltage is supplied via the evaluation unit Pin assignment Wiring 4 1 3 L 1 3 4 L DATA Information on available sockets see www ifm com Cables with the following characteristics are suitable for the connection Length Ohmic resistance feed return line Effective cable capacity 20 m max...

Страница 13: ...tage OK Off Operating voltage missing Flashing slowly deactivated yellow On permanently ID tag detected On pulse ID tag read written successfully Flashing quickly Error when reading writing on ID tag Off no ID tag in the field faulty ID tag in the field invalid ID tag in the field green and yellow Flashing alternately Error in communication or device fault ...

Страница 14: ...in case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device using a dry cloth u Dispose of the unit in accordance with the national environmental regulations ...

Страница 15: ...or approvals and standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant for approval package inserts of the device ...

Страница 16: ... used to identify objects A read write device is used to read the ID tag via a high frequency radio signal An ID tag consists of an antenna an analogue circuit for receiving and transmitting transceiver a digital circuit and a non volatile memory ...