9.2.10
EtherNet/IP: Programmers' notes
34397
The programmer can access on the following data from the PLC application:
Read device information of the AL1120
Read diagnostics and alarms
Set parameters of the connected IO-Link devices
The following sections show the available options.
Further information about the functional/operational blocks:
→ Help function of the EtherNet/IP
projection software
>
Supported EtherNet/IP configuration modes
34383
The AL1120 supports the following EtherNet/IP configuration modes:
Top down
Configuration of the EtherNet/IP slave with the EtherNet/IP projection software (Configuration
Assembly)
EtherNet/IP plc transmitts the created configuration to the EtherNet/IP slave, where it is stored
Independent
Configuration of the EtherNet/IP slave with LR DEVICE oder IoT core
Confiuration Assembly in EtherNet/IP project is not evaluated