![IFM Electronic ZB0052 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ifm-electronic/zb0052/zb0052_operating-instructions-manual_3934916008.webp)
8
5
Function
Pulling the tensioned rope, rope breakage or impact on the E-stop cause activation of
the switching function of the safety rope emergency stop switch.
There is a window on the switch via which the correct rope tension can be monitored
during setting and maintenance. Setting, troubleshooting and maintenance are made
much easier.
After activation of the E-stop function a latching mechanism maintains the E-stop
command until it is unlocked manually by pressing the blue reset button. Before
resetting the E-stop signal the cause of the activation has to be determined. Reset is
only possible with correct rope tension (position indication in middle position).
The max. rope length also depends on the change of the ambient temperature.
Function of the safety rope emergency stop switch
5.1 Maintenance requirement
Monthly:
Check proper functioning of the system at various spots along the rope length. Check
the setting of the nominal rope tension and re-adjust it, if necessary.
Every six months:
Separate the voltage supply and remove the cover. Make sure that the screws are
tight and check them for signs of penetrated moisture.
Damaged or faulty devices are to be replaced! Repair is not permissible.