28
1)
to EN50178, SELV, PELV
2)
in brackets: value displayed
3)
value for air quality class 141 (DIN 8573-1)
4)
value for air quality class 344 (DIN 8573-1)
5)
for medium flow in the limit area of the flow measurement range
All data refer to the standard volume flow to DIN ISO 2533�
12.1 Setting ranges
FLOW
SP1 / SP2
rP1 / rP2
ASP
AEP
∆Q
min
max
min
max
min
max
min
max
Nl/min
30
3750
12
3732
0
2813
937
3750
1
Nm
3
/h
1�8
225�0
0�7
223�9
0�0
168�8
56�2
225�0
0�1
Nm/s
0�9
109�2
0�4
108�7
0�0
81�9
27�3
109�2
0�1
TEMP
SP2
rP2
ASP
AEP
∆T
min
max
min
max
min
max
min
max
°C
0�4
60�0
0�2
59�8
0�0
45�0
15�0
60�0
0�2
ImPS
min
max
0�003 Nm
3
3,000,000 Nm
3
(∆Q, ∆T = step increment)