O3M151 3D Smart Sensor Object Detection
UK
Parameter name
Parameter value at factory
Data type
Array length
Min.
Max.
Physical
unit
Parameter
description
Vision
Assistant
AutoCalibParam_
numberOfPatterns
0
uint8
1
0
8
–
Number of patterns
to be used for
autocalibration (0,1
: autocalibration
disabled)
–
AutoCalibParam_xPattern 0
float32
8
-30
30
m
x coordinates [m] of
the autocalibration
patterns
–
AutoCalibParam_yPattern 0
float32
8
-30
30
m
y coordinates [m] of
the autocalibration
patterns
–
AutoCalibParam_zPattern 0
float32
8
-30
30
m
z coordinates [m] of
the autocalibration
patterns
–
AutoCalibParam_
patternType
0
uint8
8
0
10
–
type of the autocali-
bration patterns
–
twoD_mirrorX
0
uint8
1
0
1
–
Flag whether 2D
image is mirrored in
X direction
(2D imager ROI
read out back-
wards)
–
twoD_mirrorY
0
uint8
1
0
1
–
Flag whether 2D
image is mirrored in
Y direction
–
triggeredStreetCalibration 0
uint8
1
0
1
–
Flag indicating if the
triggered calibration
based on the street
plane estimation is
active
–