1  Preliminary note

1.1  Explanation of symbols

► Instruction

> Reaction, result

[…] Designation of keys, buttons or indications

→ Cross-reference

Important note 

Non-compliance can result in malfunction or interference�
Information 

Supplementary note�

2  Safety instructions

•  Please read this document prior to set-up of the unit� Ensure that the product is 

suitable for your application without any restrictions�

•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property can occur�

•  Improper or non-intended use may lead to malfunctions of the unit or to un-

wanted effects in your application� That is why installation, electrical connec-

tion, set-up, operation and maintenance of the unit must only be carried out by 

qualified personnel authorised by the machine operator�

•  In order to guarantee the correct condition of the device for the operating time 

the device must only be used in media to which the wetted parts are sufficiently 

resistant (→ Technical data).

•  The responsibility whether the measurement devices are suitable for the 

respective application lies with the operator� The manufacturer assumes no 

liability for consequences of misuse by the operator� Improper installation and 

use of the devices result in a loss of the warranty claims�

3  Functions and features

The unit detects the medium temperature and converts it into an analogue output 

signal (4 ��� 20 mA)�

Содержание Elector 600

Страница 1: ...Operating instructions Temperature transmitter with display TDxxxx 80234348 00 12 2015 UK ...

Страница 2: ... Units with G sealing cone type TD25xx 5 6 Electrical connection 6 7 Operating and display elements 7 8 Parameter setting 7 8 1 IO Link 7 8 1 1 General information 7 8 1 2 Device specific information 7 8 1 3 Parameter setting tools 8 8 2 Adjustable parameters 8 9 Operation 8 10 Technical data 9 10 1 Temperature resistance 9 11 Factory setting 9 ...

Страница 3: ...anted effects in your application That is why installation electrical connec tion set up operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator In order to guarantee the correct condition of the device for the operating time the device must only be used in media to which the wetted parts are sufficiently resistant Technical data The...

Страница 4: ...uring range scaled at OU I MAW MEW 20 6 20 4 3 7 T C F I mA I mA T C F MEW MAW AEP ASP 20 6 20 4 3 7 MAW initial value of the measuring range MEW final value of the measuring range ASP analogue start point AEP analogue end point Within the measuring range the output signal is between 4 and 20 mA If the tem perature value is outside the limits of the measuring range the following output signal is p...

Страница 5: ... lubricating paste which is suitable and approved for the application Use in hygienic areas to 3A requirements Make sure that the sensors are integrated into the system in accordance with 3A 5 1 Units with G sealing cone type TD25xx Tightening torque 30 50 Nm About sensor installation conforming to 3A Insert PEEK sealing ring E43911 Carry out installation according to separate installation instruc...

Страница 6: ...n of electrical equipment must be adhered to Voltage supply according to EN 50178 SELV PELV Disconnect power Connect the unit as follows 4 3 2 1 L L 3 1 4 2 IO Link L L 1 2 1 2 Operation as 2 wire unit 1 Pin 1 L Pin 2 Analogue signal for temperature Operation as 4 wire unit 2 Pin 1 L Pin 2 Analogue signal for temperature Pin 3 L pin 4 IO Link ...

Страница 7: ...n interface which requires an IO Link capa ble module IO Link master for operation The IO Link interface enables direct access to the process and diagnostic data and provides the possibility to set the parameters of the unit during operation In addition communication is possible via a point to point connection with a USB adapter cable You will find more detailed information about IO Link at www if...

Страница 8: ...sured value 0 is shifted by this value FOU2 Behaviour of the output in case of an internal fault ON the analogue signal goes to the upper end stop value 21 1 mA OFF the analogue signal goes to the lower end stop value 3 5 mA Uni Unit of measurement for system temperature C or F Update rate of display d1 update of the measured values every 50 ms d2 update of the measured values every 200 ms d3 upda...

Страница 9: ...ending on the medium temperature Further technical data and scale drawing at www ifm com 11 Factory setting Factory setting User setting OU I COF 0 0 FOU OFF Factory settings for the parameters ASP2 AEP2 and Uni technical data sheet at www ifm com More information at www ifm com ...

Отзывы: