background image

4

1  Preliminary note

1.1  Symbols used

Instruction

>

Reaction, result

[…] Designation of pushbuttons, buttons or indications 

Cross-reference
Important note 

Non-compliance can result in malfunction or interference�
Information 

Supplementary note�

2  Safety instructions

•  Please read this document prior to set-up of the unit� Ensure that the product is 

suitable for your application without any restrictions�

•  Work on compressed air systems as well as mounting, setting for operation 

and set-up of the unit must be carried out by qualified personnel� When doing 

so, state of the art as well as safety and accident prevention regulations have 

to be adhered to�

•  Ensure before mounting the components into or removing them from the 

compressed air system that the installation is at a standstill and no pressure is 

applied�

•  Improper or non-intended use may lead to malfunctions of the unit or to un-

wanted effects in your application� That is why installation, electrical connec-

tion, set-up, operation and maintenance of the unit must only be carried out by 

qualified personnel authorised by the machine operator�

•  Check the compatibility of the product materials (→ 11 Technical data and scale 

drawing) with the media to be measured in all applications

•  In order to guarantee the correct condition of the device for the operating time it 

is necessary to use the device only for media to which the wetted materials are 

sufficiently resistant (→ Technical data).

•  The responsibility whether the measurement devices are suitable for the 

respective application lies with the operator� The manufacturer assumes no 

Содержание efector300 SD5000

Страница 1: ...Operating instructions Compressed air meter SD5000 11406631 00 10 2013 UK...

Страница 2: ...ring analogue function 8 4 7 Setting of the standard conditions of the volume flow 9 4 8 Low flow cut off LFC 9 5 Installation 10 5 1 Installation location 10 5 2 Installation conditions 10 5 3 Instal...

Страница 3: ...3 Setting of measured value damping 21 9 5 4 Setting of the error behaviour of the outputs 21 9 5 5 Setting of the standard pressure to which the measured and display values for volumetric flow refer...

Страница 4: ...r removing them from the compressed air system that the installation is at a standstill and no pressure is applied Improper or non intended use may lead to malfunctions of the unit or to un wanted eff...

Страница 5: ...th art 3 sec 3 of the Directive 97 23 EC and are designed and manufac tured for stable gases of the fluid group 2 in accordance with sound engineer ing practice 4 Function 4 1 Processing of the measur...

Страница 6: ...The meter saves the totalled consumed quantity every 10 minutes After a power failure this value is available as the current meter reading If a time controlled reset is set the elapsed time of the set...

Страница 7: ...e signal which is proportional to the temperature 4 20 mA can be provided on output 2 Analogue functions 4 6 4 5 Volumetric flow or temperature monitoring switching function OUTx changes its switching...

Страница 8: ...8 1 2 HY hysteresis FE window 4 6 Volumetric flow or temperature monitoring analogue function 12 30 20 0 100 120 130 13 3...

Страница 9: ...splayed Minimum distance between ASP and AEP 25 of the final value of the measuring range 4 7 Setting of the standard conditions of the volume flow The unit is adjusted to a standard volume flow to DI...

Страница 10: ...stallation conditions To achieve the specified measurement accuracy the following installation condi tions must be adhered to defined inlet and outlet pipe lengths defined flow cross section area fixe...

Страница 11: ...ical fig 3 5 unit on side pipe length left fig 4 Avoid the installation position in fig 6 unit on side pipe length right If the flow rate is low the specified measurement accuracy cannot be adhered to...

Страница 12: ...1 Ub Pin 3 Ub Pin 4 OUT1 Switching signal limit values for volumetric flow Switching signal quantity meter reached preset value Pulses 1 pulse every time the defined volumetric flow quantity is reach...

Страница 13: ...eset in 103 standard cubic metres values 9999 are displayed using the 103 exponential notation LED 5 green current medium temperature in C LED 7 yellow switching status of the corresponding output LED...

Страница 14: ...M S M M M S M S M S M S M Nl min S S Nm3 h S 15s S Nm s 15s S Nm3 15s S Nm3 15s C 15s M M M M M M M S M S M S M S M S S M S M S M M M M Mode Enter Set Nm3 current meter reading in Nm3 Nm3 stored meter...

Страница 15: ...tric flow or temperature DIn2 Configuration of the input Pin2 for counter reset EF Extended functions opening of menu level 2 HI LO Maximum minimum value memory for volumetric flow FOU1 Behaviour of o...

Страница 16: ...ODD and the FDT service program ifm Container can be downloaded at www ifm com Service Download 9 1 General parameter setting 3 steps must be taken for each parameter setting 1 Parameter selection Pre...

Страница 17: ...oved via a parameter setting software Change from menu level 1 to menu level 2 Press Mode Enter until EF is displayed Press Set briefly The first parameter of the submenu is displayed here HI Locking...

Страница 18: ...function NO Fnc window function NC Select SP2 and set the value at which the output switches Select rP2 and set the value at which the output switches back 9 2 3 Setting the analogue value for volumet...

Страница 19: ...er the value for time controlled reset Press Set until the requested value is displayed intervals from 1 hour to 8 weeks then briefly press Mode Enter Press Set until rES T is displayed then briefly p...

Страница 20: ...metric flow Select Uni and set the unit of measurement Lmin volumetric flow quantity in standard litres minute nm3h volumetric flow quantity in standard cubic metres hour nmS current flow velocity in...

Страница 21: ...witches OFF in case of a fault the analogue signal goes to the lower end stop value 3 5 mA OU output 2 switches irrespective of the error as defined with the parameters The curve of the analogue signa...

Страница 22: ...ss Mode Enter briefly For the factory settings please refer to the end of these instructions 12 Factory setting We recommend taking down your own settings in that table before carrying out a reset Aft...

Страница 23: ...all 4 digits are set As soon as the first digit flashes there are 3 options Briefly press Set 1 x The flashing digit increments 9 is followed by 0 1 2 etc 8 1 2 3 SET pressed 1 x 9 1 2 3 SET pressed...

Страница 24: ...the start value After this release Set briefly and start the setting again 10 Operation Correct operation and compliance with the measurement accuracy can only be ensured if the environmental conditi...

Страница 25: ...OL Measured value 120 of the final value of the measuring range UL Measured value 20 of the final value of the measuring range temperature Err Flashing error in the measuring probe or measured value 1...

Страница 26: ...01 ImPR YES OU1 Hno OU2 I SP2 FLOW 6 00 rP2 FLOW 5 92 SP2 TEMP 24 0 rP2 TEMP 23 8 ASP FLOW 0 00 AEP FLOW 15 00 ASP TEMP 0 0 AEP TEMP 60 0 DIn2 EDG FOU1 OFF FOU2 OFF dAP 0 6 rTo OFF diS d3 Uni nm3h SEL...

Страница 27: ...27 UK...

Отзывы: