Operating instructions 

Combined pressure sensor

PN20xx

11450537 / 00

 

06 / 2010

UK

Содержание Efector 500 PN20 Series

Страница 1: ...Operating instructions Combined pressure sensor PN20xx 11450537 00 06 2010 UK...

Страница 2: ...14 9 2 1 Setting the output function 14 9 2 2 Setting the switching limits 14 9 2 3 Scaling the analogue value 14 9 3 User settings optional 15 9 3 1 Setting the unit of measurement for the system pr...

Страница 3: ...heck compliance of the product materials chapter 12 Technical data with the media to be measured Use in gases at pressures 25 bar only after contacting the manufacturer ifm For units with cULus approv...

Страница 4: ...36 25 20 290 50 725 PN2060 0 600 0 8 700 800 11 600 1 200 17 400 mbar PSI bar PSI bar PSI PN2009 1 000 1 000 14 5 14 5 20 290 50 725 PN2027 50 1 000 0 74 14 5 10 145 30 450 PN2069 500 500 7 25 7 25 1...

Страница 5: ...op tions are possible Remote display reading and display of the current system pressure Remote evaluation transfer of switching signals only with PP2001 Remote parameter setting reading and changing c...

Страница 6: ...2 Window function normally closed OUx Fnc fig 2 The width of the window can be set by means of the distance between SPx and rPx SPx maximum value rPx minimum value 1 2 P system pressure HY hysteresis...

Страница 7: ...indicated System pressure above the measuring range output signal 10 V Current output 4 20 mA Factory setting Measuring range scaled P system pressure MEW final value of the measuring range In the se...

Страница 8: ...ical equipment must be adhered to Voltage supply to SELV PELV Disconnect power Connect the unit as follows 2 x p switching 2 x n switching L L 3 4 2 1 BU BK WH BN 2 OUT2 4 OUT1 L L 3 4 2 1 BU BK WH BN...

Страница 9: ...or units with 4 adjustable units of measurement LED 7 LED 8 switching state of the respective output 9 Alphanumeric display 4 digits Indication of the current system pressure Indication of the paramet...

Страница 10: ...10 8 Menu 8 1 Menu structure...

Страница 11: ...h Analogue signal for the current system pressure 4 20 mA I or 0 10 V U ASP Analogue start point for the system pressure measured value at which 4 mA or 0 V are output AEP Analogue end point for the s...

Страница 12: ...ted continuously If the value is to be reduced Let the display move to the maximum setting value Then the cycle starts again at the minimum setting value 3 Acknowledgement of the parameter value Press...

Страница 13: ...iction Press Set briefly The first parameter of the sub menu is displayed here HI With the user interface of the ifm Container program Activate the EF button If menu level 2 is protected by an access...

Страница 14: ...teresis function normally closed Fno window function normally open Fnc window function normally closed I current signal proportional to the pressure 4 20 mA U voltage signal proportional to the pressu...

Страница 15: ...hold rd1 rd2 rd3 rPh Display like d1 d2 d3 Ph rotated by 180 OFF The display is deactivated in the operating mode 9 3 3 Zero point calibration Select COF and set a value between 5 and 5 of the final v...

Страница 16: ...requency and dAP fmax 1 2dAP 9 3 7 Setting the damping for the analogue output Select dAA set value between 0 01 4 00 s at 0 00 dAA time is not active dAA value response time between pressure change a...

Страница 17: ...e Enter briefly to scroll the parameters Press Set briefly to indicate the corresponding parameter value for 15 s After another 15 s the unit returns to the Run mode 10 2 Fault indication OL overload...

Страница 18: ...18 11 Scale drawing Dimensions are in millimeters 1 dimensions for PN2060 1 display 2 LED s 3 programming button...

Страница 19: ...in load with voltage output 2000 Min response time analogue output ms 3 Communication interface IO Link 1 0 Baud rate kBAUD 38 4 Accuracy deviations in of the span 2 Accuracy of switch point 0 4 Chara...

Страница 20: ...N2069 IP 65 Protection class III Insulation resistance M 100 500 V DC Shock resistance g 50 DIN IEC 68 2 27 11ms Vibration resistance g 20 DIN IEC 68 2 6 10 2000 Hz Switching cycles min 100 million 50...

Страница 21: ...2720 905 3625 5 MPa 0 20 25 00 0 10 24 90 0 00 18 57 6 25 25 00 0 05 PN2022 bar 0 8 100 0 0 4 99 6 0 0 75 0 25 0 100 0 0 2 PSI 12 1450 6 1444 0 1088 364 1450 2 MPa 0 08 10 00 0 04 9 96 0 00 7 50 2 50...

Страница 22: ...12 5 187 5 50 0 250 0 0 5 mmWS 105 2550 115 2540 125 1910 510 2550 5 kPa 1 05 25 00 1 15 24 90 1 25 18 75 5 00 25 00 0 05 inH2O 4 2 100 4 4 6 100 0 5 0 75 4 20 2 100 4 0 2 PN2060 bar 6 600 2 596 0 45...

Страница 23: ...N2069 500 mbar AEP 100 VMR COF 0 dS1 0 0 dr1 0 0 dS2 0 0 dr2 0 0 P n PnP dAP 0 06 dAA 0 10 diS d2 Uni bAr mbAr the indicated percentage of the final value of the measuring range of the correspond ing...