• Fasten mounting elements within zone M.
• Mounting elements must be fixed above the measuring segment
OP
and at a minimum distance to
OP
(see value y, measured to the
middle of the segment).
• The probe must comply with
minimum distances
to the tank wall,
metallic objects in the tank (B), tank bottom and further level sen-
sors. The distances x, y and w depend on the medium set (
MEDI
).
29
ENGLISH
Mounting
L (probe length)
M (mounting zone)
LK8122
LK8123
LK8124
cm
inch
26.4
10.4
14
5.5
cm
inch
47.2
18.6
23
9.1
cm
inch
72.8
28.7
36
14.2
w
y
u
v
B
OP
x
M
L
cm
2.0
2.5
4.5
6.0
1.0
4.5
4.0
inch
0.8
1.0
1.8
2.4
0.4
1.8
1.6
MEDI
=
CLW1
x
y (LK8122)
u
v
w
y (LK8123)
y (LK8124)
cm
3.0
3.5
5.5
7.0
1.0
4.5
5.0
inch
1.2
1.4
2.2
2.8
0.4
1.8
2.0
MEDI
=
CLW2, OIL1
cm
4.0
4.5
6.5
8.0
1.0
4.5
6.0
inch
1.6
1.8
2.6
3.2
0.4
1.8
2.4
MEDI
=
OIL2